Skip to content
VINscan

RECALLS — MAKE · MODEL · YEAR

2012 Tiffin Phaeton recalls

13 safety recall campaigns have been filed for the 2012 Tiffin Phaeton with Transport Canada and the U.S. NHTSA. Here is what both agencies say.

Canadian recalls
06
U.S. recalls
07
Total campaigns
13

Transport Canada recalls

06
  • Steering#2018226

    82 units affected

    On certain vehicles built on a Freightliner XBR chassis, a rubber-coated braided power steering hose may have inadequate clearance to the starter power stud due to incorrect routing. This could cause the power steering hose to rub against the stud on the starter motor, which could cause an electrical arc and a power steering fluid leak. A power steering leak in the presence of an electrical arc could increase the risk of fire causing injury and/or damage to property. A power steering fluid leak could also require additional steering effort which could increase the risk of a crash causing injury and/or damage to property. Correction: Daimler Trucks of North America Service Facilities will reroute the power steering hose to ensure proper clearance to starter stud.

  • Accessories#2018046

    1,653 units affected

    On certain motorhomes equipped with Kidde fire extinguishers with black plastic handles and valves, the fire extinguishers may become clogged or require excessive force to activate. Also, the nozzle may detach from the valve assembly with enough force that it could cause injury, and fail to discharge. In case of fire, failure of the extinguisher to function could result in injury and/or property damage. Correction: Owners will be provided with instructions on how to inspect the fire extinguisher to see if it is recalled. Replacement fire extinguishers will be supplied by Kidde directly. Note: For more information about recalled fire extinguishers, please visit <a href="https://inmarmarketaction.com/kidde/Kidde284CA/">www.kidde.com</a>.

  • Structure#2017163

    3 units affected

    On certain vehicles built on a Powerglide chassis, insufficient clearance exists between the exhaust pipe and the floor. This could cause the floor insulation to melt and make the floor area above the engine extremely hot, increasing the risk of personal injury or possibly resulting in a fire. Correction: Dealers will install a revised exhaust configuration to increase clearance. Note: This is an expansion of recall 2015-565.

  • Accessories#2016035

    1,093 units affected

    On certain motorhomes equipped with Lippert Components Inc. electric entry steps, an internal bolt on the steps that attaches the fan gear assembly to the steps could fracture. This results in the fan gear disengaging from the steps, which could cause the steps to stop in an unexpected position and appear to be loose or unstable. If the steps become unstable, it could cause a person to fall, resulting in injury. Correction: Dealers will install a step retainer bracket to reinforce the operating mechanism, and all bolts of the mechanism will also be replaced.

  • Engine#2015565

    10 units affected

    On certain vehicles built on a Powerglide chassis, insufficient clearance exists between the exhaust pipe and the floor. This could cause the floor insulation to melt and make the floor area above the engine extremely hot, increasing the risk of personal injury or possibly resulting in a fire. Correction: Dealers will install a revised exhaust configuration to increase clearance.

  • Electrical#2013009

    153 units affected

    On certain vehicles, the connector for the brake and cruise control signal diode jumper assembly may come loose, resulting in a possible intermittent or continuously open circuit. Two circuits are potentially affected. One circuit disengages the cruise control with brake pedal application, and the other circuit illuminates the brake lights with brake application. Failure of the cruise control to disengage, or of the brake lights to illuminate when the brake pedal is depressed, could result in a crash causing property damage and/or personal injury. Correction: Dealers will verify that the locking tabs on the diode jumper assembly connector are fully engaged and locked into place.

Canadian data updated August 24, 2026

U.S. NHTSA recalls

07
  • EQUIPMENT#17V841000

    Tiffin Motorhomes, Inc. (Tiffin) is recalling certain 2009-2018 Allegro and Allegro RED, Bus and Phaeton vehicles, 2009-2010 Bay vehicles, 2011-2018 Breeze vehicles, and 2009-2015, and 2017-2018 Zephyr vehicles. These motorhomes are equipped with Kidde Plastic-Handle or Push Button 'Pindicator' Fire Extinguishers that may become clogged, preventing the extinguisher from discharging as expected or excessive force may be needed to activate the extinguisher. Additionally, in certain models, the nozzle may detach from the valve assembly with enough force that it could cause injury and also render the product inoperable. For a full list of the affected fire extinguisher models visit: https://static.nhtsa.gov/odi/rcl/2017/RMISC-17E062-5427.pdf

    Risk: In the event of a fire, if the fire extinguisher does not function properly, it can increase the risk of injury.

    Remedy: Tiffin will notify owners, and instruct them to contact Kidde for a replacement fire extinguisher, free of charge. The recall began on February 5, 2018. Owners may contact Kidde customer service toll-free at 1-855-262-3540, or online at www.kidde.com and click on "Product Safety Recall" for more information. Owners may also contact Tiffin customer service at 1-256-356-8661.

  • ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:MANIFOLD/HEADER/MUFFLER/TAIL PIPE#17V121000

    Tiffin Motorhomes, Inc. (Tiffin) is recalling certain 2012 Phaeton motorhomes with floor plans QBH, QKH, and QTH, built on PowerGlide chassis. The affected vehicles have an exhaust pipe that is mounted too close to the underside of the floor.

    Risk: Insufficient spacing between the exhaust pipe and the floor may result in the insulation melting and an increased risk of a fire.

    Remedy: Tiffin will notify owner, and dealers will reconfigure the exhaust to provide extra clearance, free of charge. The recall began on March 22, 2017. Owners may contact Tiffin customer service at 1-256-356-8661. Tiffin's number for the recall is TIF-106.

  • EQUIPMENT:RECREATIONAL VEHICLE/TRAILER#15V880000

    Tiffin Motorhomes (Tiffin) is recalling certain model year 2007-2015 motorhomes manufactured May 1, 2007, to December 31, 2014, equipped with certain Coachstep Double and Triple Electric Steps. The bolt that attaches the fan gear assembly to the steps may fracture allowing the fan gear to disengage from the steps. As a result, the steps may not remain in the expected position and may become unstable.

    Risk: Unstable entry and exit steps increase the risk of injury.

    Remedy: Dealers will install a retainer bracket on the double step assemblies and the Coachstep Linkage Assembly will be replaced and a retainer bracket will be installed on the trip step assemblies. The recall began on Ferbuary 10, 2016. Owners may contact Tiffin customer service at 1-256-356-8661, or Lippert customer service at 1-574-537-8900.

  • ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:MANIFOLD/HEADER/MUFFLER/TAIL PIPE#15V612000

    Tiffin Motorhomes, Inc. (Tiffin) is recalling certain model year 2010-2012 Phaeton motorhomes built on Powerglide chassis with floor plans QBH, QKH, and QTH manufactured July 1, 2010, to August 1, 2011. The affected vehicles have an exhaust pipe that is mounted too close to the underside of the floor.

    Risk: Insufficient spacing between the exhaust pipe and the floor may result in the insulation melting and an increased risk of a fire.

    Remedy: Tiffin will notify owners, and dealers will change the configuration of the exhaust to provide extra clearance between it and the floor, free of charge. The recall began on December 1, 2015. Owners may contact Tiffin customer service at 1-256-356-8661. Note: Although these vehicles may have been previously repaired for this condition under recall number 11V-416, it is important that the affected vehicles receive the revised remedy of this recall.

  • SERVICE BRAKES, AIR#12V228000

    TIFFIN MOTORHOMES (TIFFIN) IS RECALLING TWO MODEL YEAR 2012 PHAETON RECREATIONAL VEHICLES BUILT ON A SPARTAN CHASSIS AND EQUIPPED WITH 3030 BRAKE CHAMBERS. THESE VEHICLES FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NUMBER 121, “AIR BRAKE SYSTEMS” BECAUSE THEY DO NOT MEET THE PARK BRAKE AND DRAW BAR REQUIREMENTS.

    Risk: THE PARK BRAKE MAY NOT BE SUFFICIENT TO HOLD THE VEHICLE IN PLACE. ACCORDINGLY, THE VEHICLE COULD ROLL AWAY AND STRIKE AND INJURE A BYSTANDER OR CAUSE A CRASH WITHOUT WARNING.

    Remedy: THE AFFECTED VEHICLES HAVE NOT BEEN SOLD YET AND TIFFIN HAS NOTIFIED THE DEALERS THAT ARE IN POSSESSION OF THE VEHICLES. SPARTAN DEALERS WILL INSTALL IMPROVED BRAKE CHAMBERS PRIOR TO SALE. OWNERS MAY CONTACT TIFFIN MOTORHOMES AT 1-256-356-8661.

  • ENGINE AND ENGINE COOLING#12V048000

    TIFFIN IS RECALLING CERTAIN MODEL YEAR 2011, 2012, AND 2013 RECREATIONAL VEHICLES, MODELS PHAETON AND ZEPHYR, EQUIPPED WITH A CUMMINS ISB, ISC, ISL, OR ISX DIESEL ENGINE. THE V-BAND CLAMP ASSEMBLY, PART NUMBERS Q187684, Q187685, AND Q187686, USED TO CONNECT THE INLET AND OUTLET CONE SECTIONS TO THE DIESEL OXIDATION CATALYST (DOC)/DIESEL PARTICULATE FILTER (DPF) INCLUDE A T-BOLT WHICH CAN FRACTURE AND FAIL WHEN SUBJECTED TO STRESS OR LOAD. A FRACTURE OR FAILURE OF THE T-BOLT MAY CAUSE THE CLAMP TO LOOSEN AND THE INLET OR OUTLET SECTIONS ATTACHED TO THE DOC/DPF HOUSING TO DISCONNECT.

    Risk: IF THE INLET OR OUTLET SECTIONS DISCONNECT, HOT EXHAUST GASES CAN VENT PRIOR TO EXITING THE TAILPIPE, CREATING THE RISK OF COMBUSTION AND A FIRE. IF BOTH CLAMPS FAIL, THERE IS A RISK IN SOME APPLICATIONS THAT THE DOC/DPF HOUSING MAY DETACH COMPLETELY, CREATING A ROAD HAZARD.

    Remedy: TIFFINS IS WORKING WITH CUMMINS TO IDENTIFY AND NOTIFY OWNERS OF THE RECALL CAMPAIGN. REPAIRS WILL BE PERFORMED BY AUTHORIZED CUMMINS DEALERS FREE OF CHARGE. OWNERS MAY CONTACT CUMMINS AT 1-812-377-5000 OR TIFFINS AT 256-356-8661.

  • ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:MANIFOLD/HEADER/MUFFLER/TAIL PIPE#11V416000

    TIFFIN IS RECALLING CERTAIN MODEL YEAR 2010-2012 PHAETON MOTORHOMES WITH FLOOR PLANS QBH, QKH, AND QTH THAT ARE BUILT WITH 2010 EPA-CERTIFIED ENGINES ON POWERGLIDE CHASSIS. THE EXHAUST PIPE IS MOUNTED TOO CLOSE TO THE UNDERSIDE OF THE FLOOR.

    Risk: MELTING OF THE INSULATION CAN OCCUR, POSSIBLY RESULTING IN A FIRE.

    Remedy: TIFFIN WILL NOTIFY OWNERS, AND DEALERS WILL ATTACH A HEAT SHIELD TO THE BOTTOM OF THE FLOOR AND AN INSULATING SOCK OR BLANKET WILL BE WRAPPED AROUND THE EXHAUST PIPE. THESE REPAIRS WILL BE PERFORMED FREE OF CHARGE. THE RECALL BEGAN ON SEPTEMBER 19, 2011. OWNERS MAY CONTACT TIFFIN AT 1-256-356-8661.

Does this recall apply to my vehicle?

Matched by make, model, and model year. Many recalls affect only specific VIN ranges — confirm with your dealer using your full VIN.

What to do

Recall repairs are free at a franchised dealer in both countries. To confirm a recall applies to your specific vehicle, or to book the work, contact your manufacturer or dealer with your full VIN, or use the official channel:

Check a 2012 Tiffin Phaeton VIN

A VIN decode confirms your vehicle's exact model year, trim and assembly plant, then runs this same recall check against it.

Data sources and coverage limits